For use in PV Waterheating Systems
Description
Use as a geyser timer
- Clear display of water temperature, time, day, heating mode and malfunction conditions.
- Auto or manual heating.
- Easy temperature setting to your requirements (30 – 65°C) factory default is 55°C.
- Four different temperature settings.
- Daily programmable timer with four time settings.
- Error conditions alert by warning code E1 to E7.
- Electronic thermostat with mechanical thermal cut-out at 90°C.
Use as timer and controller on GeyserWise PV waterheating system
- Clear display of water temperature, time, day, heating mode and malfunction conditions on PV system and geyser.
- Auto or manual heating.
- Easy temperature setting to your requirements (30 – 65°C) factory default is 55°C for AC and 65°C for DC.
- Four different temperature settings.
- Daily programmable timer with four time settings.
- Error conditions alert by warning code E1 to E7.
- Electronic thermostat with mechanical thermal cut-out at 90°C.
- LDR control to control AC vs DC mode of water heating.
Technical Parameters
- Operating voltage 230VAC / 50HZ.
- Main relay contact rating 20AMP (Max 3kW element).
- Operating voltage range 160V – 250VAC.
- Control circuit 5.5 – 12VDC.
- Earth leakage protection at 25mA action time ≤ 0,1 second.
- Recommended ambient temperatures: -20 to 55°C; Max 75°C.
- Temperature range 0 – 200°C (“-5” when below -5°C).
- DC on at set light value up to 75°C.
- DC differential between 3 – 7°C (control DC element in on or off state).
- 230 VAC temperature setting ranges 30 – 65°C.
- 230 VAC heat failure – when increase at a rate of 4°C or less per hour.
- Mechanical thermal cut-out 90°C (300 manual resets).
- Thermal cut-out – Isolate live.
- Dry heat detection – empty cylinder.
- Temperature tolerance ± 5°C and manufacturing drift is less than 6°C.
- Temperature differential setting 1°C.
- 230 VAC switching differential for the element 6°C.
- LDR sensor for light detection.
- LDR settable 150 – 200 value
- Temperature probe failure detection for tank.
- Temperature probe range for geyser is -30 to +130°C.
- Light level 1 range 0 – 230.
- Isolate both L + N when element in an off state.
- Control box insulated – Class 1.
- Operating life – 50 000 cycles.